Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.973
Filtrar
1.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38619382

RESUMO

¼ Posterior glenohumeral instability is relatively uncommon compared with anterior instability, but is becoming an increasingly recognized and surgically managed shoulder pathology.¼ Soft-tissue stabilization alone may not be sufficient in patients who present with substantial bone loss to the posterior glenoid and/or the anterior humeral head.¼ For posterior glenoid defects, posterior glenoid osteoarticular augmentation can be used, and posterior glenoid opening wedge osteotomy can be considered in cases of posterior instability with pathologic retroversion.¼ For humeral head lesions, several surgical treatment options are available including subscapularis transposition into the humeral head defect, autograft or allograft reconstruction, humeral rotation osteotomy, and shoulder arthroplasty.


Assuntos
Instabilidade Articular , Articulação do Ombro , Humanos , Ombro , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Escápula , Cabeça do Úmero/cirurgia
2.
BMC Musculoskelet Disord ; 25(1): 305, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643086

RESUMO

BACKGROUND: Historically, in-person physical therapy serves as a foundational component of nonoperative treatment of adhesive capsulitis (AC). This study compares the effectiveness of an at-home high-intensity stretch (HIS) device to traditional physical therapy (PT) and to PT in combination with the HIS device. We hypothesize that the HIS device will be as effective as PT alone or as combination therapy in the first-line treatment of AC and use of the HIS device will exhibit improvement at higher rate. METHODS: Thirty-four patients with idiopathic adhesive capsulitis and a minimum of 12 months follow-up were included in this study. Patients were randomized into one of the three groups: HIS device, PT alone, or HIS device + PT. Passive range of motion (ROM), American Shoulder and Elbow Surgeons (ASES), and Simple Shoulder Test (SST) scores were measured. Additionally, patient satisfaction, compliance and complications were recorded. Paired t-test, ANOVA and Chi-squared tests were used in analysis. RESULTS: Final ROM in all planes improved for all groups compared to baseline (p < 0.001), with only HIS device group able to restore > 95% of contralateral ROM in all planes at final follow-up. Patients with PT alone were on average slowest to improve ROM from baseline, at 3 months, 6 months, and 1 year in all planes except internal rotation. ASES and SST scores improved for all groups when compared to baseline (p < 0.001). Use of HIS-device resulted in greater improvement in SST and ASES Total scores compared to PT alone (p = 0.045, and p = 0.048, respectively). CONCLUSIONS: Use of an at-home high-intensity stretching device for conservative treatment of idiopathic adhesive capsulitis improves outcomes in ROM and in ASES and SST scores both when used as an adjunct to physical therapy and when used alone. TRIAL REGISTRATION: The study protocol was registered at www. CLINICALTRIALS: gov (20/05/2022, NCT05384093).


Assuntos
Bursite , Articulação do Ombro , Humanos , Resultado do Tratamento , Estudos Prospectivos , Bursite/terapia , Bursite/complicações , Modalidades de Fisioterapia , Amplitude de Movimento Articular
3.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 505-510, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632074

RESUMO

Objective: To review the research progress of ultrasound in the diagnosis and treatment of shoulder diseases, in order to provide a theoretical basis for the further development of ultrasound in shoulder surgery. Methods: The recent literature on the application of ultrasound in the shoulder joint was extensively reviewed. The application of ultrasound in the diagnosis and treatment of shoulder joint diseases, and the advantages and disadvantages of ultrasound were analysed, and the development trend of ultrasound technology in the shoulder joint area was prospected. Results: At present, the diagnosis of shoulder joint diseases mainly relies on MRI, however, with the development of ultrasound technology, ultrasound with the characteristics of convenient, reliable, and real-time dynamic evaluation is more and more recognized in the diagnosis process of shoulder joint diseases, combined with three-dimensional ultrasound, ultrasound intervention, and elastography can improve the accuracy, sensitivity, and specificity of the diagnosis, and is suitable for the diagnosis and treatment of various shoulder joint diseases, which is expected to carry out early prevention of shoulder joint diseases in the future and achieve more refined and minimally invasive treatment. Conclusion: Ultrasound technology has wide application prospect in shoulder joint diseases, but it is still in the developing stage, and the subjective dependence needs to be solved further.


Assuntos
Artropatias , Articulação do Ombro , Humanos , Ultrassonografia , Imageamento por Ressonância Magnética , Ombro
4.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637350

RESUMO

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Atividades Cotidianas , Escápula/diagnóstico por imagem , Escápula/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
5.
Med Sci Monit ; 30: e943703, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38637980

RESUMO

BACKGROUND This retrospective study investigated the association between the critical shoulder angle (CSA) and the development of full-thickness rotator cuff tears (FTRCTs) in the Turkish population. The CSA is an imaging parameter that quantifies the relationship between the inclination of the glenoid and the lateral extension of the acromion in the coronal plane. The CSA is an anatomical measurement, and higher CSA values have been associated with an increased incidence of FTRCTs. However, there is a lack of data on CSA regarding the Turkish population. MATERIAL AND METHODS In this study, CSA measurements were recorded in 2 groups: 50 patients with FTRCT who had arthroscopic repair (group 1) and 50 age- and sex-matched individuals with no FTRCT detected by magnetic resonance imaging (group 2). Sex, age, affected side, dominant side, and smoking status were recorded for each patient. The CSA measurements of the affected sides were performed on true anterior-posterior view radiographs. RESULTS The results showed a statistically significant difference between the mean CSA values of group 1 (37.48°) and group 2 (33.53°), P<0.001. CSA values of 36 and above had a sensitivity of 73.58%, specificity of 74.47%, positive predictive value of 75%, and negative predictive value of 74.47% for detecting FTRCT. CONCLUSIONS CSA measurement on radiographs is a useful diagnostic tool in the Turkish population, and an above-average CSA value is associated with a significantly increased incidence of degenerative-type FTRCT.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Ombro/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico por imagem , Estudos de Coortes , Estudos Retrospectivos
6.
PLoS One ; 19(4): e0301320, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630752

RESUMO

Movement systems are massively redundant, and there are always multiple movement solutions to any task demand; motor abundance. Movement consequently exhibits 'repetition without repetition', where movement outcomes are preserved but the kinematic details of the movement vary across repetitions. The uncontrolled manifold (UCM) concept is one of several methods that analyses movement variability with respect to task goals, to quantify repetition without repetition and test hypotheses about the control architecture producing a given abundant response to a task demand. However, like all these methods, UCM is under-constrained in how it decomposes a task and performance. In this paper, we propose and test a theoretical framework for constraining UCM analysis, specifically the perception of task-dynamical affordances. Participants threw tennis balls to hit a target set at 5m, 10m or 15m, and we performed UCM analysis on the shoulder-elbow-wrist joint angles with respect to variables derived from an affordance analysis of this task as well as more typical biomechanical variables. The affordance-based UCM analysis performed well, although data also showed thrower dynamics (effectivities) need to be accounted for as well. We discuss how the theoretical framework of affordances and affordance-based control can be connected to motor abundance methods in the future.


Assuntos
Movimento , Articulação do Ombro , Humanos , Movimento/fisiologia , Articulação do Ombro/fisiologia , Fenômenos Biomecânicos
7.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562639

RESUMO

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Escápula , Amplitude de Movimento Articular , Fenômenos Biomecânicos
8.
Clin Orthop Surg ; 16(2): 294-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562643

RESUMO

Background: There are few reports on the revision or reintervention of reverse total shoulder arthroplasty (RTSA) in South Korea. The purpose of this study was to evaluate the true incidence of complications and reintervention of RTSA and clinical and radiological outcomes based on our 14-year experience in RTSA in a Korean population. Methods: Between March 2008 and June 2022, 412 consecutive cases of RTSA were performed in 388 patients with an average age of 74.4 years at our institute. Excluding 23 patients lost to follow-up, 365 patients (373 shoulders including 8 bilateral cases) who underwent primary RTSA with more than 6 months of follow-up were enrolled in this study. We evaluated those who had complications or reintervention including revision RTSA for failed RTSA. Patient charts were reviewed, and clinical outcomes including clinical scores, complications, and reintervention and radiologic outcomes were evaluated at the last follow-up. Results: Among the 373 shoulders that underwent primary RTSA, complications were found in 50 patients (13.94%, 10 men and 40 women with a mean age of 75.9 ± 6.7 years [range, 51-87 years]). The causes of complications were as follows: 13 acromion, coracoid, or scapular spine fractures, 10 loosening (glenoid: 5, humeral stem: 5), 5 infections, 4 periprosthetic fractures, 2 instability, 2 neurologic complications, and 14 miscellaneous complications. Twenty patients (5.63%, 4 men and 16 women with a mean age of 74.2 ± 8.2 years [range, 51-87 years]) underwent reintervention. The interval to the first reintervention was 27.8 ± 23.1 months (range, 0.1-78 months). The causes of reintervention (20 cases) were 8 loosening (glenoid: 4, humeral stem: 4), 5 infections, 5 fractures, and 2 instability. Among them, 15 component revisions (4.02%) were performed. At the last follow-up, American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Simple Shoulder Test scores were improved from 25.4, 12.4, and 1.6 preoperatively to 40.4, 16.2, and 3.2, respectively. Forward flexion (48° to 87°), abduction (52° to 79°), external rotation (18° to 22°), and internal rotation (buttock to L2) were improved. Conclusions: After primary RTSA in a Korean population, the complication, reintervention, and revision rates were 13.94%, 5.63%, and 4.02%, respectively. Careful evaluation of the complications and adequate treatments should be performed.


Assuntos
Artroplastia do Ombro , Fraturas Periprotéticas , Articulação do Ombro , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento , Fraturas Periprotéticas/etiologia , Escápula , Estudos Retrospectivos , Amplitude de Movimento Articular , Reoperação/efeitos adversos
9.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574183

RESUMO

¼ Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function.¼ Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture.¼ Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application.¼ A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Manguito Rotador/cirurgia
10.
J Orthop Surg Res ; 19(1): 222, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576016

RESUMO

BACKGROUND: To compare the histopathological results of biceps tenodesis (BT) performed with normal, low, and high pressures for superior capsule reconstruction (SCR) in rabbits with massive rotator cuff tears. MATERIALS AND METHODS: Thirty rabbits were divided into three groups. Rabbits 1-10 underwent SCR with BT at the same pressure (Group 1), value measured in the groove; 50% lower (Group 2); 50% higher (Group 3). After the 4-week follow-up, shoulder were en-bloc excised and histopathological evaluation was performed with modified Bonar's scale. Results were compared between the groups, statistically. RESULTS: Extracellular matrix were significantly lower in group 2 compared to the other groups (p < 0.05). Cellularity levels were significantly lower in group 2 compared to the other groups (p < 0.05). Group 2 had no difference between the sides (p > 0.05). Group 2 had lower vascularity levels compared to the other groups (p = 0.01). DICSUSSION: When the biceps tendon was in the bicipital groove and in a more mobile state with lower pressure exposure. BT performed with a tension that creates less pressure than the biceps in the groove is more successful in SCR.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Tenodese , Coelhos , Animais , Tenodese/métodos , Músculo Esquelético/cirurgia , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Tendões/cirurgia , Tendões/patologia , Braço/cirurgia , Articulação do Ombro/cirurgia , Artroscopia/métodos
11.
Am J Sports Med ; 52(5): 1292-1298, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38506922

RESUMO

BACKGROUND: The glenoid track concept is used to determine preoperatively whether a Hill-Sachs defect is engaging or not. Currently, the glenoid track concept relies on measurements of bony structures as well as on the confines and elasticity of the rotator cuff as a reference point, which varies extensively among individuals and therefore limits the reliability and accuracy of this concept. PURPOSE: To evaluate the reliability of the global track concept, which determines the angular distance of the Hill-Sachs defect from the center of the articular surface of the humeral head as a new reference point with the help of an automated image analysis software and 3-dimensional analysis of the humeral head. STUDY DESIGN: Controlled laboratory study. METHODS: Computed tomography scans of 100 patients treated for anterior shoulder instability with different sizes of Hill-Sachs defects were evaluated manually by 2 orthopaedic surgeons independently using the software OsiriX as well as automatically by using a dedicated prototype software (ImFusion). Obtained manual and automated measurements included the Hill-Sachs length, Hill-Sachs width, and Hill-Sachs depth of the defect; the Hill-Sachs interval (HSI); and the glenoid width for the glenoid track concept, as well as the angular distance of the Hill-Sachs defect from the center of the articular surface of the humeral head (global track concept). The reliability of the different measurement techniques was compared by calculating intraclass correlation coefficients (ICCs). RESULTS: There was a significant difference for all obtained parameters comparing manual and automatic measurements. For manually obtained parameters, measurements referring to bony boundaries (glenoid width, Hill-Sachs length, and Hill-Sachs width) showed good to excellent agreement (ICC, 0.86, 0.82, and 0.62, respectively), while measurements referring to soft tissue boundaries (HSI and glenoid track; ICC, 0.56 and 0.53, respectively) or not directly identifiable reference points (center of articular surface and global track) only showed fair reliability (ICC middle excursion, 0.42). When the same parameters were measured with the help of an automated software, good reliability for the glenoid track concept and excellent reliability for the global track concept in the middle excursion were achieved. CONCLUSION: The present study showed that the more complex global track measurements of humeral defects are more reliable than the current standard HSI and glenoid track measurements. However, this is only true when automated software is used to perform the measurements. CLINICAL RELEVANCE: Future studies using the new proposed method in combination with an automated software need to be conducted to determine critical threshold values for defects prone to engagement.


Assuntos
Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Reprodutibilidade dos Testes , Ombro , Luxação do Ombro/diagnóstico por imagem , Luxação do Ombro/cirurgia , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia
12.
Am J Sports Med ; 52(5): 1299-1307, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38488401

RESUMO

BACKGROUND: Constitutional static posterior humeral decentering (type C1 according to ABC Classification) has been recognized as a pre-osteoarthritic deformity that may lead to early-onset posterior decentering osteoarthritis at a young age. Therefore, it is important to identify possible associations of this pathologic shoulder condition to find more effective treatment options. PURPOSE: To perform a comprehensive analysis of all parameters reported to be associated with a C1 shoulder-including the osseous shoulder morphology, scapulothoracic orientation, and the muscle volume of the shoulder girdle in a single patient cohort. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: A retrospective, comparative study was conducted analyzing 17 C1 shoulders in 10 patients who underwent magnetic resonance imaging (MRI) with the complete depiction of the trunk from the base of the skull to the iliac crest, including both humeri. The mean age of the patients was 33.5 years, and all patients were men. To measure and compare the osseous shoulder morphology (glenoid version, glenoid offset, humeral torsion, anterior acromial coverage, posterior acromial coverage, posterior acromial height, and posterior acromial tilt) and scapulothoracic orientation (scapular protraction, scapular internal rotation, scapular upward rotation, scapular translation, scapular tilt, and thoracic kyphosis), these patients were matched 1 to 4 according their age, sex, and affected side with shoulder-healthy patients who had received positron emission tomography (PET)-computed tomography. To measure and compare the muscle volume of the shoulder girdle (subscapularis, infraspinatus/teres minor, supraspinatus, trapezius, deltoid, latissimus dorsi/teres major, pectoralis major, and pectoralis minor), patients were matched 1 to 2 with patients who had received PET-MRI. Patients with visible pathologies of the upper extremities were excluded. RESULTS: The C1 group had a significantly higher glenoid retroversion, increased anterior glenoid offset, reduced humeral retrotorsion, increased anterior acromial coverage, reduced posterior acromial coverage, increased posterior acromial height, and increased posterior acromial tilt compared with controls (P < .05). Decreased humeral retrotorsion showed significant correlation with higher glenoid retroversion (r = -0.742; P < .001) and higher anterior glenoid offset (r = -0.757; P < .001). Significant differences were found regarding less scapular upward rotation, less scapular tilt, and less thoracic kyphosis in the C1 group (P < .05). The muscle volume of the trapezius and deltoid was significantly higher in the C1 group (P < .05). CONCLUSION: Patients with C1 shoulders differ from healthy controls regarding osseous scapular and humeral morphology, scapulothoracic orientation, and shoulder girdle muscle distribution. These differences may be crucial in understanding the delicate balance of glenohumeral centering.


Assuntos
Instabilidade Articular , Cifose , Articulação do Ombro , Masculino , Humanos , Adulto , Feminino , Ombro/diagnóstico por imagem , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiologia , Estudos Transversais , Escápula/diagnóstico por imagem , Escápula/fisiologia , Manguito Rotador
13.
J Biomech ; 166: 112055, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38522362

RESUMO

Glenohumeral biomechanics after rotator cuff (RC) tears have not been fully elucidated. This study aimed to investigate the muscle compensatory mechanism in weight-bearing shoulders with RC tears and asses the induced pathomechanics (i.e., glenohumeral translation, joint instability, center of force (CoF), joint reaction force). An experimental, glenohumeral simulator with muscle-mimicking cable system was used to simulate 30° scaption motion. Eight fresh-frozen shoulders were prepared and mounted in the simulator. Specimen-specific scapular anthropometry was used to test six RC tear types, with intact RC serving as the control, and three weight-bearing loads, with the non-weight-bearing condition serving as the control. Glenohumeral translation was calculated using instantaneous helical axis. CoF, muscle forces, and joint reaction forces were measured using force sensors integrated into the simulator. Linear mixed effects models (RC tear type and weight-bearing) with random effects (specimen and sex) were used to assess differences in glenohumeral biomechanics. RC tears did not change the glenohumeral translation (p > 0.05) but shifted the CoF superiorly (p ≤ 0.005). Glenohumeral translation and joint reaction forces increased with increasing weight bearing (p < 0.001). RC and deltoid muscle forces increased with the presence of RC tears (p ≤ 0.046) and increased weight bearing (p ≤ 0.042). The synergistic muscles compensated for the torn RC tendons, and the glenohumeral translation remained comparable to that for the intact RC tendons. However, in RC tears, the more superior CoF was close to where glenoid erosion occurs in RC tear patients with secondary osteoarthritis. These findings underscore the importance of early detection and precise management of RC tears.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Humanos , Ombro/fisiologia , Manguito Rotador/fisiologia , Articulação do Ombro/fisiologia , Fenômenos Biomecânicos , Suporte de Carga , Cadáver , Amplitude de Movimento Articular/fisiologia
14.
Int Orthop ; 48(5): 1285-1294, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38478022

RESUMO

PURPOSE: Prevalence of axillary (AN) and/or suprascapular (SSN) neuropathy in rotator cuff tear arthropathy (RCTA) is unknown. We aimed to prospectively evaluate for preoperative neurodiagnostic abnormalities in order to determine their prevalence, location, and influence on reverse shoulder arthroplasty (RSA) outcomes. METHODS: Patients who underwent RSA for RCTA were prospectively included. An electromyography and nerve conduction study were performed pre and post-surgery. Clinical situation: VAS, Relative Constant-Murley Score (rCMS) and ROM over a minimum of two years follow-up. RESULTS: Forty patients met the inclusion criteria; mean follow-up was 28.4 months (SD 4.4). Injuries in RCTA were present in 83.9% (77.4% in AN and 45.2% in SSN). There were no differences on preoperative VAS, ROM, and rCMS between patients with and without preoperative nerve injuries. Four acute postoperative neurological injuries were registered under chronic preoperative injuries. Six months after RSA, 69% of preoperative neuropathies had improved (82.14% chronic injuries and 77.7% disuse injuries). No differences in improvement between disuse and chronic injuries were found, but patients with preoperative neuropathy that had not improved at the postoperative electromyographic study at six months, scored worse on the VAS (1.44 vs 2.66; p .14) and rCMS (91.6 vs 89.04; p .27). CONCLUSIONS: The frequency of axillary and suprascapular neuropathies in RCTA is much higher than expected. Most of these injuries improve after surgery, with almost complete neurophysiological recovery and little functional impact on RSA. However, those patients with preoperative neuropathies and absence of neurophysiological improvement six months after surgery have lower functional results.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Artropatia de Ruptura do Manguito Rotador , Articulação do Ombro , Humanos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/diagnóstico , Lesões do Manguito Rotador/cirurgia , Estudos Prospectivos , Ombro/cirurgia , Articulação do Ombro/cirurgia , Articulação do Ombro/inervação , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Resultado do Tratamento , Estudos Retrospectivos , Amplitude de Movimento Articular
15.
J Biomech ; 166: 112019, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38479149

RESUMO

A few reports on scapular motion during shoulder joint extension exist. Understanding the normal motion of shoulder joint extension may be useful in evaluating and treating patients with diminished or minimal shoulder joint extension. Therefore, this study aimed to identify scapular motion during shoulder joint extension movement in a sitting position. Shoulder joint extension movement in the sitting position were measured in 22 healthy adults (age, 25.8 ± 2.7 years). Shoulder joint extension, scapular upward rotation, anterior tilt, external rotation angles, and the acromion position were investigated using a three-dimensional motion analyzer. The difference from each value of 10° to 50° shoulder joint extension to each value of 0° shoulder joint extension were checked. The results were compared using multiple comparison method. In most participants, the scapula tilted posteriorly up to 30° of the shoulder joint extension and anteriorly after 30°. Scapular upward and external rotation continued to increase with shoulder extension. Furthermore, the acromion was displaced upward and backward. Thus, scapular posterior tilt is necessary for shoulder joint extension during the initial movement, followed by anterior tilt. The acromion may have been displaced posteriorly because of clavicular retraction, causing the scapula to tilt posteriorly. After 30° of shoulder joint extension, the scapular anterior tilt may have prevailed over the scapular posterior tilt.


Assuntos
Articulação do Ombro , Adulto , Humanos , Adulto Jovem , Fenômenos Biomecânicos , Escápula , Ombro , Movimento , Amplitude de Movimento Articular , Rotação
16.
J Orthop Surg Res ; 19(1): 180, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475917

RESUMO

BACKGROUND: Reverse Shoulder Arthroplasties (RSA) have become a primary choice for improving shoulder function and pain. However, the biomechanical failure mechanism of the humeral component is still unclear. The present study reports a novel protocol for microstructural imaging of the entire humerus implant under load before and after fracture. METHODS: A humerus specimen was obtained from a 75-year-old male donor. An expert surgeon implanted the specimen with a commonly used RSA implant (Aequalis reversed II, Stryker Orthopaedics, USA) and surgical procedure. The physiological glenohumeral contact force that maximized the distal implant migration was selected from a public repository ( orthoload.com ). Imaging and concomitant mechanical testing were performed using a large-volume micro-CT scanner (Nikon XT H 225 ST) and a custom-made compressive stage. Both when intact and once implanted, the specimen was tested under a pre-load and by imposing a constant deformation causing a physiological reaction load (650 N, 10 degrees adducted). The deformation of the implanted specimen was then increased up to fracture, which was identified by a sudden drop of the reaction force, and the specimen was then re-scanned. RESULTS: The specimen's stiffness decreased from 874 N/mm to 464 N/mm after implantation, producing movements of the bone-implant interface consistent with the implant's long-term stability reported in the literature. The micro-CT images displayed fracture of the tuberosity, caused by a combined compression and circumferential tension, induced by the distal migration of the implant. CONCLUSION: The developed protocol offers detailed information on implant mechanics under load relative to intact conditions and fracture, providing insights into the failure mechanics of RSA implants. This protocol can be used to inform future implant design and surgical technique improvements.


Assuntos
Fraturas Ósseas , Articulação do Ombro , Masculino , Humanos , Idoso , Ombro , Articulação do Ombro/cirurgia , Extremidade Superior , Úmero/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular
17.
PLoS One ; 19(3): e0296948, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38478545

RESUMO

The somatosensory system is a complect sensory system that differentiates individual athletes. The aim of this study is to investigate the effect of visual acuity level on throwing technique, proprioceptive sense of the shoulder joint, light touch and two-point discrimination sense of the upper extremity, and sensory function (postural control and reaction time) in visually impaired goalball players. Goalball players who have different visual acuities B1(unable to perceive light or recognize its shape); B2 (has a visual field of less than 5 degrees and can recognize shapes); B3 (visual field greater than 5 degrees and less than 20 degrees) participated in the study. The sensorial system was evaluated with proprioceptive sense of the shoulder joint and sensory tests (light touch and two-point discrimination sense of the dominant hand.). Sensory function (postural control and reaction time) was evaluated with the flamingo balance test, functional reach test, and pro-agility test. The goalball players' throwing technique was questioned. Seventeen male players, those aged 20-30 (20.8±3.9 years) who have been professionally engaged in goalball for at least three years (58.7-37.8 months) participated. Shoulder internal rotation joint position sense and the flamingo balance test were found to be different in the group with B1 visual acuity than in the group with B3 visual acuity (p = 0.042* and 0.028 respectively). There was no difference between groups with B1-B2 visual acuity (p = 0.394 and p = 0.065) and between groups with B2-B3 visual acuity (p = 0.792 and p = 0.931). There was no difference in the groups in terms of sensory tests and reaction time (p> 0.05). In goalball, joint position sense is related to throwing techniques. Although there is a general acceptance that other sensory systems should work harder to compensate for the sense of vision, fear of falling, athlete's branch year, sports year, muscle strength, and general physical condition of the athlete may affect the measurements made, especially in the dynamic position.


Assuntos
Medo , Articulação do Ombro , Humanos , Masculino , Estudos Transversais , Amplitude de Movimento Articular/fisiologia , Articulação do Ombro/fisiologia , Propriocepção , Acuidade Visual
18.
JBJS Rev ; 12(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38466801

RESUMO

¼ The proximal humerus is a common location for primary bone tumors, and the goal of surgical care is to obtain a negative margin resection and subsequent reconstruction of the proximal humerus to allow for shoulder function.¼ The current evidence supports the use of reverse total shoulder arthroplasty over hemiarthroplasty when reconstructing the proximal humerus after resection of a bone sarcoma if the axillary nerve can be preserved.¼ There is a lack of high-quality data comparing allograft prosthetic composite (APC) with endoprosthetic reconstruction of the proximal humerus.¼ Reverse APC should be performed using an allograft with donor rotator cuff to allow for soft-tissue repair of the donor and host rotator cuff, leading to improvements in shoulder motion compared with an endoprosthesis.


Assuntos
Neoplasias Ósseas , Osteossarcoma , Articulação do Ombro , Humanos , Ombro/cirurgia , Ombro/patologia , Estudos Retrospectivos , Úmero/cirurgia , Osteossarcoma/cirurgia , Osteossarcoma/patologia , Neoplasias Ósseas/patologia
19.
Int Biomech ; 11(1): 1-8, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38501436

RESUMO

Altered scapular kinematics is associated with shoulder pain. Resistance exercise is a common treatment; however, the effects of lifting an external load on scapular kinematics is limited. Understanding whether an external handheld load affects scapular kinematics in a healthy population can provide normal values utilized for comparison to individuals with shoulder pain. Currently, no studies have examined the effect of incrementally increased handheld loads. We defined the effects of varying external handheld loads on scapular kinematics during a shoulder elevation task. Healthy participants (n = 50) elevated their shoulder in the scapular plane over 4 trials. One trial of no loading (control) and 3 trials with incrementally increased external handheld loads. Scapular kinematic rotations and translations were measured during ascent and descent phases using 3D motion capture. Compared to no load, the highest external load during ascent increased scapular elevation [mean difference = 3.2 degrees (95%CI: 0.9, 5.4), p = 0.006], and during descent increased scapular elevation [mean difference = 3.9 degrees (95%CI: 2.8, 5.1), p < 0.001] and increased scapular upward rotation [mean difference = 4.5 degrees (95%CI: 2.4, 6.6), p < 0.001]. External handheld loads result in small increases in scapular elevation and scapular upward rotation. These results should be utilized as normal values to compare to individuals with shoulder pain.


Assuntos
Articulação do Ombro , Ombro , Humanos , Dor de Ombro , Amplitude de Movimento Articular , Escápula
20.
J Orthop Surg Res ; 19(1): 193, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38504340

RESUMO

BACKGROUND: The importance of several scapulothoracic muscles, including trapezius and serratus anterior, in maintaining physiological scapula kinematics has been highlighted in the past. However, the relationship between the scapula and the latissimus dorsi muscle remains unclear. Our clinical surgical observation is that the latissimus dorsi does not directly attach but rather runs superficial to the inferior angle of the scapula. Based on this observation, we hypothesise that the latissimus dorsi creates a dynamic track on which the scapula glides under the muscle belly during elevation of the arm, creating the latissimus-scapula overlap (LSO). METHODS: All consecutive patients who had a whole-body computed tomography scan (CT) in case of polytrauma evaluation between 2018 and 2021, with complete depiction of the scapula and latissimus dorsi muscle, were analysed. 150 shoulders in 90 patients with arms up were matched according to their age (within five years), gender, and affected side with 150 shoulders in 88 patients with arms down. Patients with pathologies of the upper extremities or thorax that potentially could alter LSO measurements were excluded. LSO was calculated as a ratio of the measured area of the latissimus dorsi projection on the scapula and the total scapula area. RESULTS: The mean age of the 178 patients (48 females; 13 males) was 60 years. The arms-up group showed a significantly higher LSO than the arms-down group (19.9 ± 6.3% vs. 2.7 ± 2.2%; p < 0.0001). In the arms-up group, approximately one fifth of the scapula was overlapped inferiorly by the muscle belly of the latissimus dorsi, contrary to the almost non-existing LSO in the arms-down group. CONCLUSION: With arms up, humans show a significantly higher LSO in comparison to arms down indicating that the latissimus dorsi indeed creates a dynamic track on which the scapula is forced to travel during abduction of the arm. This finding of increased LSO during the elevation of the arm warrants further consideration of the role of the latissimus dorsi in scapula kinematics and potentially scapular dyskinesis. LEVEL OF EVIDENCE: Level two diagnostic study.


Assuntos
Anormalidades Congênitas , Escápula/anormalidades , Articulação do Ombro/anormalidades , Músculos Superficiais do Dorso , Masculino , Feminino , Humanos , Pré-Escolar , Músculos Superficiais do Dorso/diagnóstico por imagem , Braço/diagnóstico por imagem , Escápula/cirurgia , Ombro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...